lichtzen-ae logo.gif

 

 

 

 

     LICHTZEN AE      

 

 

 

 

 

 

 

  

 

 

 

About us  |  E-mail  |  Board  |  Site Map

 

   

 

 

  Home > Instruments > 광 계측기기
img53.gif
  광 계측기기 (OPTICAL INSTRUMENTS)  

 

 

 

 

 

 

 

DETECTORS

 

 

detectors for radiometers, photometers,light measurement instruments

 

 

Our nomenclature for identifying detection assemblies is shown below. For many applications the detector/filter/input optic configuration best suited the measurement is specified in the application package. For example, a detector for making photopic measurements with an IL1700 would be specified as follows: SED033/Y/W. This common combination is listed as the IL1710 Research Photometer.

 

SED

detector class and matching meter (XXL for IL1400 series, XXD for IL1700 series)

033

specifies the type photodiode and spectral range

/Y

specifies filter(s) used. In the example above, the Y refers to our photopic filter

/w

specifies the foreoptics used for illuminating the detector. In our example, the W indicates our wide-eye diffuser.

The SED and SEL type detector housings are made of black anodized aluminum, with female filter threads (1¼-24), a tripod mount (¼-20), and two end mounts (#8-32).

 

 

Photo Detectors

 

001

Silicon Carbide

210nm to 380 nm

005

Galium Phosphide

250nm to 675 nm

007

InGaAs

850nm to 1700nm

033

33mm2 Silicon

200nm to 1100nm

100

100mm2 Silicon

200nm to 1100nm

240

Solar Blind vacuum photodiode

185nm to 320nm

623

Thermopile detector

200nm to 4000nm

 

 

 

 

Input Optics

W

Wide Eye Diffuser

R

Radiance Barrel

L30

High Gain Lens

H

Hood

K#

Cone where # is the hole aperture

T,T2X

Teflon Diffuser

SR

Spectroradiometer Input Optics

FFO

Fiber Optic Assembly

 

  

Filters

 

Y

Photopic

F

Flat response corrector

ZCIE

Scotopic

QNDS#

Broadband attenuator where # (1,2,3) are factors of 10 attenuation

NS###

Narrow band filters where ## is the central wavelength in nm

WBS###

Wide bandpass filters where ### is the central wavelength in nm

SCC###

Sharp cut on filters where ### is the center of the transition band

TXXX

Broadband color filters where XXX indicates the color (Red, BLUE)

 

Filters and input optics can dramatically alter a detector's spectral and spatial responsivity.

 

NOTE: The dynamic ranges given for each detector apply for use with the IL1700

(SED type).

To view the specifications for any detector, click on the detector name.

 

 


The /U following the part numbers below indicates an UNCALIBRATED sensor.
Detector kits such as SED033/Y/W include a calibration therefore the /U is not noted in the part number. The SED, SHD and SEL type detector housings are made of black anodized aluminum, with female filter threads (1¼-24), a tripod mount (¼-20), and two end mounts (#8-32). Only these housings allow for filter selection/swapping and only the SED and SEL type housings allow for underwater modification. All underwater modified SED or SEL detectors require the W wide-eye diffuser in addition to any other filters. The SCxxx detectors are in a 112 x 17 x 16 mm wand style housing, The XRxxx are in a 12.5 x 42 mm dia. housing, the SPxxx are in a 121 x 19 mm dia. pen style housing. These three version do not have removable, swappable filters and cannot be made waterproof.

 

 

 

 

 

DETECTORS

Part Number/Description

Spectral Range

Specifications

SCD110/U, IL1700 Illuminance Probe

400-700 nm, Photopic

5.8 mm² active area silicon detector with built in CIE VIS response filter in wand style detector housing. Dimensions: 112 x 17 x 16 mm. UNCALIBRATED.

SCL110/U, IL1400 Illuminance Probe



SCD144/U, IL1700 Bilirubin Phototherapy Probe

422-488 nm, 450 nm peak

5.8 mm² active area silicon detector with built in filter in wand style detector housing. Dimensions: 112 x 17 x 16 mm. UNCALIBRATED.

SCL144/U, IL1400 Bilirubin Phototherapy Probe



SCD145/U, IL1700 Phototherapy Probe

360-525 nm, 450 nm peak

5.8 mm² active area silicon detector with built in filter in wand style detector housing. Dimensions: 112 x 17 x 16 mm. UNCALIBRATED.

SCL145/U, IL1400 Phototherapy Probe



SED005/U, IL1700 UV-Visible GaAsP Detector

250-675 nm, 610 nm peak

5.2 mm² detector with quartz window. Dimensions: 20 x 42 mm dia. UNCALIBRATED.

SEL005/U, IL1400 UV-Visible GaAsP Detector



SUD005/U or SUL005/U, Underwater version



SED007/U, IL1700 IR InGaAs Detector

850-1700 nm, 1455 nm peak

7 mm² detector with spectral range from 850-1700nm. Dimensions: 20 x 42 mm dia. UNCALIBRATED.

SEL007/U, IL1400 IR InGaAs Detector



SUD007/U or SUL007/U, Underwater version



SED033/U, IL1700 Broadband Silicon Detector

200-1100 nm, 950 nm peak

33 mm² silicon detector with quartz window. Dimensions: 20 x 42 mm dia. UNCALIBRATED.

SEL033/U, IL1400 Broadband Silicon Detector



SUD033/U or SUL033/U, underwater version



SED100/U, IL1700 Broadband Silicon Detector

200-1100 nm, 950 nm peak

100 mm² (1 cm2) silicon detector with quartz window. Dimensions: 20 x 42 mm dia. UNCALIBRATED.

SEL100/U, IL1400 Broadband Silicon Detector



SUD100/U or SUL100/U, underwater version



SED185/U, IL1700 Gold Cathode Detector

160-240 nm, 185 nm peak

50 mm² active area Au Cathode Vacuum photodiode with quartz window (visible blocking). Good stability in high ozone / UV environment. Dimensions: 53 x 42 mm dia. UNCALIBRATED.

SEL185/U, IL1400 Gold Cathode Detector



SED220/U, IL1700 Solar Blind Detector

160-320 nm, 220 nm peak

50 mm² active area Vacuum photodiode with fused silica window (visible blocking). Dimensions: 53 x 42 mm dia. UNCALIBRATED.

SEL220/U, IL1400 Solar Blind Detector



SUD220/U or SUL220/U, underwater version



SED240/U, IL1700 Solar Blind Detector,

185-320 nm, 240 nm peak

50 mm² active area Vacuum photodiode with quartz window (visible blocking). Dimensions: 53 x 42 mm dia. UNCALIBRATED.

SEL240/U, IL1400 Solar Blind Detector



SUD240/U or SUL240/U, underwater version



SED320/U, IL1700 UV
Gallium Nitride Detector

200-320 nm, flat

0.076 mm² active area gallium nitride detector. Provides uniform sensitivity from 200 to 320 nm. Dimensions: 20 x 42 mm dia. UNCALIBRATED.

SEL320/U, IL1400 UV
Gallium Nitride Detector



SUD320/U or SUL320/U, underwater version



SED324/U, IL1700 Broadband Silicone Detector

320-1100 nm, 960 nm peak

Large 324 mm² active area silicone detector. Dimensions: 20 x 42 mm dia. UNCALIBRATED.

SEL324/U, IL1400 Broadband Silicone Detector



SUD324/U or SUL324/U underwater version



SED365/U, IL1700 UV
Gallium Nitride Detector

200-365 nm, flat

0.076 mm² active area gallium nitride detector. Provides uniform sensitivity from 200 to 365 nm. Dimensions: 20 x 42 mm dia. UNCALIBRATED.

SEL365/U, IL1400A UV
Gallium Nitride Detector



SUD365/U or SUL365/U, underwater version



SED623/U, IL1700 Thermopile Detector

200-4200 nm, flat > 700 nm

4 mm² thermopile detector with quartz window. Dimensions: 60 x 42 mm dia. UNCALIBRATED.

SEL623/U, IL1400 Thermopile Detector



SED624/U, IL1700 Thermopile Detector

0.2-40 micron, flat > 1.0 micron

4 mm² thermopile detector with KBr window. Dimensions: 60 x 42 mm dia. UNCALIBRATED.

SEL624/U, IL1400 Thermopile Detector